Introduction
Treatment of distal radius fractures is difficult due to comminution and joint involvement.1 These fractures are unstable & difficult to reduce. They are accompanied by complications which include reduced grip strength, limited motion, carpal stability, malunion, distal radioulnar joint subluxation/dislocation and late disruption of fracture. Multiple procedures like reduction and cast appliation, external fixator application, k wire fixation leads to a poor functional outcome.2 The resulting deformity of the wrist causes pain, movement limitation and wrist joint arthritis.3 Restoration of normal alignment and articular surface, with a stable fixation and/or bone grafting can be difficult, but it is needed for a good functional outcome. The fracture reduction directly correlates to the outcome.4 The plate reconstruction offers fracture reduction directly as well as a stable fixation. Another important benefits are early post-operative mobilization and rehabilitation.5 With the use of Lock Compression Plate(LCP), small bone piece can be held together.6, 7 Thus, this study aims to evaluate the role of the volar plate fixation as the treatment method of choice for distal radius fractures and compare it with other results.8, 9
Materials and Methods
35 cases of fracture distal end radius operated by open reduction and internal fixation by volar locking plates from December 2012 to March 2017 in our institution were reviewed who fulfilled the inclusion criteria. 7 patients were lost in follow-up. Hence records of a total of 28 cases were available for this study.
Inclusion criteria
Adults(age>18yrs and < 60yrs), AO type B&C, Displaced intra articular fracture distal radius with 1) volar or dorsal angulation of >100,2)radial inclination <150, 3) intraarticular step off >2mm, 4)>5 mm of shortening by ulnar variance on the posteroanterior radiographic view, fractures < 3 weeks old.
Exclusion criteria
Unfit for anesthesia, skeletal immaturity, pathological fractures, compound fractures, polytrauma, known alcohol or drug dependency, inability to participate in the study, neuromuscular disorder & Inflammatory arthritis. Patients participating in other clinical trials of a drug or device were also excluded. The mean age of 20 male patients and 8 female patients was 36.86 years (Range from 18-56 years). The most common mechanism of injury was a fall on outstretched hand. Nineteen patients had their dominant limb fractured. Fracture radius was classified by the AO Classification system as follows: Type B1 in 3 cases, B2 in 2 cases, B3 in 11 cases, C1in 6 cases, C2 in 3 cases and C3 in 3 cases. Most cases were surgically treated within first week of the injury. (range 0-14 days).
Surgical procedure
After taking written informed consent of inclusive criteria patient to OT. Patient were taken up for open reduction and fixation with Anatomically contoured Volar locking plate. Of the 35 patients, 15 underwent Surgical fixation under general anesthesia while remaining 20 underwent brachial plexus block. The procedure was done in supine position. A Pneumatic tourniquet was used in all cases. Using the standard Volar (Henry’s) approach, intermuscular plane was developed between brachioradialis & FPL. Radial and distal borders of the pronator quadratus muscle were elevated and retracted. Fracture site was exposed subperiosteally. Fracture fragments were curetted and anatomic reduction achieved with the help of manual distraction, intrafocal leverage, or dis-engaging the fracture. Temporary fixation by Kirschner wires was done. Volar locking plate was fixed and confirmed in C Arm machine. Additional stabilization, if found necessary, was done either with k-wires. After fixation, pronator quadrates muscle was attached to its insertion with absorbable sutures. Postoperatively plaster splint was applied in supination and 100-150 palmar flexion till suture removal. Active and passive finger motion exercises were encouraged post operatively. Post-operatively, Sitting up in the bed was allowed once the brachial block effect was over. 1st check dress was done on day 2 & Post-operative X-Ray was taken. On the 5th postoperative day the patient was discharged after 2nd check dress. Stitch removal was done usually on 11th Post operative day and splint was removed. Patients were started on wrist and finger range of motion exercises. Both active as well as passive movements were encouraged. Prayer stretch for extension of the wrist, passive flexion, Forearm rotation for supination/pronation, Grip strengthening by ball in the hand exercises, Grasping, opposition and pinch exercises, Elbow flexion and extension, Shoulder flexion, abduction and extension exercises were taught by a physiotherapist and encouraged. Weight lifting was prohibited for at least 12 weeks after operation. All patients were followed up at 1 month, 3 months, 6 months, and 1 year post-operatively. At the time of each visit of patients, anteroposterior and lateral view Xrays of both wrists were done. They were assessed for reduction and bony union, volar tilt, radial inclination, radial height, and ulnar variance. Range of motion was evaluated at each visit. Scoring was done by modified Gartland and Werley scoring system.10
Results
Patients were traced for a minimum duration of one year. (range: 12-24 months).
Radiographic parameters assessment revealed average radial height, radial inclination, ulnar variance and palmar tilt, calculated at one to three months was found to be 8±1.mm, 17±4 degrees, −0.1±0.6 mm, and 7± 5 degrees respectively. At the end of 12 month of visit, the average radial height, radial inclination, ulnar variance, and palmar tilt changed to 8±1.2 mm, 17±4 degrees, −0.1±1.9 mm, and 7± 5.1 degrees respectively. No significant difference x-ray parameters were noted at the end of 12month follow-up, indicating no further appreciable collapse of fracture and maintained reduction in due course of time. The flexion at the end of 12month of follow-up was 60± 9 degrees and extension 50±10 degrees. The average supination was 77±11 degrees and pronation 84±5 degrees at 12month of follow-up as shown below. [Figure 1]
90% of patients reported pain grading on the visual analog scale one or less than one at 12 weeks and at final follow-up.
In our series; [Figure 2].
At the final follow-up.
Excellent results in 17 cases out of 28 cases in which most of the excellent results in AO type B fractures (excellent outcome in 13patients out of 16patients i.e. 81.25% cases) as compared to type C fracture where it was 33.33% cases (excellent outcome in 4 patients out of 12 patients).
Good results in 6cases out of 28 cases out of which mostly patients were AO type C fractures.
Fair results in 3 cases out of 28 cases.
Poor results in 2 cases out of 28 cases which were in AO type C fractures.
So plating has a better outcome in AO type B fractures, While equivocal results in type C fractures.
One patient developed superficial skin infection on the 5th postop day which was resolved around the 10th postoperative day and the rest of the period was uneventful. So overall complication was reported in one patient. None of the case had any nerve palsy, tendon rupture, nonunion or implant failure.
Gartland & Werley's score improved in due course of time at final follow up mean Gartland & Werley score was around 2 which was excellent. [Figure 2]. Poor results can be because of poor reduction of fracture fragments.
Discussion
Stable fixation along with joint surface reduction is the primary goal in the treatment of distal radius fractures. Secondary goal is to prevents secondary arthritis and poor functional outcome.3 Various treatment modalities for distal radius fracture fixation includes close/open reduction and cast application, k-wire fixation, external fixator, plates application.11 Volar plate approach offers spacious distal radius suitable for implant fixation. Also, its application technique is relatively simple and prevents damage to the blood supply which is important for bony union. Locking plates are especially useful in osteoporotic fractures to prevent fracture collapse. The single unit plate and screw locking construct holds and supports the bony fragments. Plating offers direct visualization of fracture fragments helpful in anatomy restoration, early mobilization and hence early and better return of wrist function and hence reduce morbidity.12 Numerous complications are described with plating which includes risk of infection, tendon irritation, tendon rupture requiring implant extraction in few cases. 13 The pronators quadrates muscle act as a barrier to minimize flexor tendon irritation. 14 In our study, pronation improved more rapidly as compared to supination. While both returned to near normal at the end of final visit. No significant collapse of the fracture occurred at the end of 12 months.
Our results compared favorably with existing literature. In 2010 Gerald Gruber et al reported >90% of patients had excellent to good results by Gartland and Werley score after plate fixation of distal radius.15 Similar results are seen in our study too. Another study by David H. Wei. Et al (2009), reported better DASH scores after locking volar plate fixation comparable to our study. 16 Anatomical reduction and stable internal fixation is the primary goal of treatment for intrarticular distal radius fracture. Limitations of our study included relatively shorter follow up, lack of controls and lack of variety of fracture patterns.
Conclusion
Our study demonstrates that locking compression plate offers a good method of treatment for articular distal radius fractures. Reduction is maintained with lock compression plates in due course of time so that secondary displacement doesn’t occur. Also, early return to functional activity can occur with vigorous physiotherapy. Based on our results, we opine that excellent functional outcome can be obtained in AO-type B fracture with volar locking compression plates. However, role of volar plating in AO-type C fracture is inconclusive and needs further studies to prove its role.